台达 MS300 是精巧矢量型变频器,常用于风机、水泵、传送带等轻载场景,故障代码清晰、参数易调试,但现场常遇到上电、过流、过压、端子控制、参数异常等问题。以下是OCD 减速过流代码 + 成因 + 一步到位解决方案。
OCD :减速过流
成因:
减速太快、大惯性负载、回馈电流过大
解决:
1.延长 01-08 减速时间
2.加装制动电阻、启用制动功能(07-01=1)
台达变频器MS300系列完整型号
1. 单相 230V (1P 230V) — 功率:0.2~2.2kW
VFD1A6MS21ANSAA (0.2kW, 1.6A)
VFD2A8MS21ANSAA (0.4kW, 2.8A)
VFD4A8MS21ANSAA (0.75kW, 4.8A)
VFD7A5MS21ANSAA (1.5kW, 7.5A)
VFD11AMS21ANSAA (2.2kW, 11A)
2. 三相 230V (3P 230V) — 功率:0.2~15kW
VFD1A6MS23ANSAA (0.2kW, 1.6A)
VFD2A8MS23ANSAA (0.4kW, 2.8A)
VFD4A8MS23ANSAA (0.75kW, 4.8A)
VFD7A5MS23ANSAA (1.5kW, 7.5A)
VFD11AMS23ANSAA (2.2kW, 11A)
VFD17AMS23ANSAA (3.7kW, 17A)
VFD25AMS23ANSAA (5.5kW, 25A)
VFD33AMS23ANSAA (7.5kW, 33A)
VFD49AMS23ANSAA (11kW, 49A)
VFD59AMS23ANSAA (15kW, 59A)
3. 三相 460V (3P 460V) — 功率:0.4~22kW
VFD2A8MS43ANSAA (0.4kW, 2.8A)
VFD4A2MS43ANSAA (0.75kW, 4.2A)
VFD5A5MS43ANSAA (1.5kW, 5.5A)
VFD9A0MS43ANSAA (2.2kW, 9A)
VFD13AMS43ANSAA (3.7kW, 13A)
VFD17AMS43ANSAA (5.5kW, 17A)
VFD24AMS43ANSAA (7.5kW, 24A)
VFD32AMS43ANSAA (11kW, 32A)
VFD38AMS43ANSAA (15kW, 38A)
VFD45AMS43ANSAA (18.5kW, 45A)
VFD59AMS43ANSAA (22kW, 59A)
工易自营