台达 MS300 是精巧矢量型变频器
常用于风机、水泵、传送带等轻载场景,故障代码清晰、参数易调试,但现场常遇到上电、过流、过压、端子控制、参数异常等问题。
以下是OCN恒速过流代码 + 成因 + 一步到位解决方案。
成因:
负载突变、堵转、三相不平衡、电机卡死
解决:
1.检查机械卡滞
2.正确设置电机额定电流(05-01)
3.放大变频器功率一档
台达 MS300 是精巧矢量型变频器选型型号
1. 单相 230V (1P 230V) — 功率:0.2~2.2kW
VFD1A6MS21ANSAA (0.2kW, 1.6A)
VFD2A8MS21ANSAA (0.4kW, 2.8A)
VFD4A8MS21ANSAA (0.75kW, 4.8A)
VFD7A5MS21ANSAA (1.5kW, 7.5A)
VFD11AMS21ANSAA (2.2kW, 11A)
2. 三相 230V (3P 230V) — 功率:0.2~15kW
VFD1A6MS23ANSAA (0.2kW, 1.6A)
VFD2A8MS23ANSAA (0.4kW, 2.8A)
VFD4A8MS23ANSAA (0.75kW, 4.8A)
VFD7A5MS23ANSAA (1.5kW, 7.5A)
VFD11AMS23ANSAA (2.2kW, 11A)
VFD17AMS23ANSAA (3.7kW, 17A)
VFD25AMS23ANSAA (5.5kW, 25A)
VFD33AMS23ANSAA (7.5kW, 33A)
VFD49AMS23ANSAA (11kW, 49A)
VFD59AMS23ANSAA (15kW, 59A)
3. 三相 460V (3P 460V) — 功率:0.4~22kW
VFD2A8MS43ANSAA (0.4kW, 2.8A)
VFD4A2MS43ANSAA (0.75kW, 4.2A)
VFD5A5MS43ANSAA (1.5kW, 5.5A)
VFD9A0MS43ANSAA (2.2kW, 9A)
VFD13AMS43ANSAA (3.7kW, 13A)
VFD17AMS43ANSAA (5.5kW, 17A)
VFD24AMS43ANSAA (7.5kW, 24A)
VFD32AMS43ANSAA (11kW, 32A)
VFD38AMS43ANSAA (15kW, 38A)
VFD45AMS43ANSAA (18.5kW, 45A)
VFD59AMS43ANSAA (22kW, 59A)